30. Typed clocks and multirate ticks
Status: partly implemented. This is roadmap R13 (spec stage 10). The library profile in
coax/lib/clock.coaxruns incoax0: instants typed by clock, conversions that name their source, sample-and-hold connections with a maximum age, tick schedules in a fixed order, the UTC, TAI, TT and TDB scales over a pinned leap-second table, and time warp that stops at every event. Thetask @ratesyntax, compiler-enforced clock-read effects (R11) and adoption by the robot and the OpenAgents Metaverse loops are planned.
A simulation reads several clocks. Simulation time can pause, scale or jump. Steady time only moves forward. Civil time follows a calendar and can be corrected. A program that keeps all three as plain integers can subtract one from another and get a number that means nothing. In this chapter, you give each clock its own instant type, connect tasks that run at different rates, convert between astronomical time scales, and run a warped clock that still lands on every scheduled event.
Instants carry their clock (runs today)
A clock is an empty tag struct. An instant is a nanosecond count in an s64 with the tag as a type parameter, so Instant(Sim) and Instant(Steady) are different types. The library declares Sim, Steady, Civil, UTC, TAI, TT and TDB, and a constructor for each, such as sim_at(ns). A literal that names its clock, such as Instant(Sim).{ns = 0}, works too:
Instant :: struct($C: copyable) { ns: s64; }// An instant on one clock, from its nanosecond count.sim_at :: (ns: s64) -> Instant(Sim) { r: Instant(Sim); r.ns = ns; return r; }steady_at :: (ns: s64) -> Instant(Steady) { r: Instant(Steady); r.ns = ns; return r; }civil_at :: (ns: s64) -> Instant(Civil) { r: Instant(Civil); r.ns = ns; return r; }utc_at :: (ns: s64) -> Instant(UTC) { r: Instant(UTC); r.ns = ns; return r; }tai_at :: (ns: s64) -> Instant(TAI) { r: Instant(TAI); r.ns = ns; return r; }tt_at :: (ns: s64) -> Instant(TT) { r: Instant(TT); r.ns = ns; return r; }tdb_at :: (ns: s64) -> Instant(TDB) { r: Instant(TDB); r.ns = ns; return r; }elapsed :: (later: Instant($C: copyable), earlier: Instant($C)) -> s64 { return later.ns - earlier.ns;}elapsed binds $C from its first argument, and its second argument must have the same clock. Integer nanoseconds keep every sum exact, so a replay gets the same instants. When physics code needs seconds, seconds(ns) turns a span into chapter 29's Quantity(Second, f64).
Pass instants from two clocks, and the compiler refuses the call. The program is `examples/ch30_clocks_refused.coax`:
#import "Basic";#load "../../lib/clock.coax" as clock;main :: () { sim := clock.sim_at(5000); wall := clock.steady_at(9000); print("%\n", clock.elapsed(wall, sim)); // refused: two clocks}$ coax run examples/ch30_clocks_refused.coaxexamples/ch30_clocks_refused.coax:7:36: error[E0348]: '$C' is Steady from another argument of 'elapsed', but argument 2 is Sim print("%\n", clock.elapsed(wall, sim)); // refused: two clocks ^ fix: pass the same type; a struct or array does not convert with cast1 errorA clock tag is a struct with no value, so nothing converts to it with a cast. To compare a steady instant with a simulation instant, convert one of them explicitly, as the next section shows.
Conversions name their source
Clock_Map(From, To) holds a pinned offset and a source: a number that identifies where the offset came from, such as a recorded mapping or a configuration. map_clock(m, at) returns a Mapped(To) with the converted instant and that source, so a converted instant says how it was converted. There is no conversion without a map.
Sample-and-hold with a maximum age
Tasks that run at different rates share values through a connection. Hold(T, C) keeps the latest value, when it was written and how old a reader may see it. hold_get returns a Held(T): the value and its age, or an error.
hold_get :: (h: Hold($T: copyable, $C: copyable), now: Instant($C)) -> Held($T) { result: Held($T); if !h.written { result.error = Hold_Error.empty; return result; } age := now.ns - h.at.ns; result.age_ns = age; if age < 0 { result.error = Hold_Error.future; return result; } if age > h.max_age_ns { result.error = Hold_Error.stale; return result; } result.value = h.value; return result;}A read past the maximum age is Hold_Error.stale, not a silently stale value. The error is a value the caller must look at (chapter 7). A stale or failed read returns a zero value, never the old one.
Tick schedules run in a fixed order
A Rate_Task runs at its phase and then every period. `schedule_due(tasks, now, out) writes the indices of the tasks due at now into out`, in their declared order. Given the rates and phases, the order is the same on every run. The program `examples/ch30_ticks.coax` runs physics at 1 kHz, control at 500 Hz and telemetry at 100 Hz from 1 ms. Control reads the joint angle that physics wrote, at most 4 ms old. After four ticks the simulation pauses: physics stops writing, and control's next read is stale.
#import "Basic";#load "../../lib/clock.coax" as clock;// Physics at 1 kHz, control at 500 Hz, telemetry at 100 Hz starting 1 ms in.NAMES :: [3] string.["physics", "control", "telemetry"];main :: () { tasks := [3] clock.Rate_Task.[ clock.Rate_Task.{period_ns = 1000000, phase_ns = 0}, clock.Rate_Task.{period_ns = 2000000, phase_ns = 0}, clock.Rate_Task.{period_ns = 10000000, phase_ns = 1000000}]; // Control reads the joint angle physics wrote, at most 4 ms old. angle: clock.Hold(f64, clock.Sim) = clock.Hold.{max_age_ns = 4000000}; due: [3] s64; for tick: 0..<4 { now := clock.sim_at(tick * 1000000); count := clock.schedule_due(tasks[..], now, due[..]); print("t=% ms:", tick); for i: 0..<count { print(" %", NAMES[due[i]]); } print("\n"); for i: 0..<count { if due[i] == 0 { angle = clock.hold_put(angle, 0.1 * cast(f64) tick, now); } if due[i] == 1 { r := clock.hold_get(angle, now); print(" control reads % (age % ns, %)\n", r.value, r.age_ns, r.error); } } } // Pause the simulation: physics stops writing, and control's read goes stale. late := clock.hold_get(angle, clock.sim_at(8000000)); print("after a pause, control at 8 ms reads % (age % ns, %)\n", late.value, late.age_ns, late.error);}$ coax run examples/ch30_ticks.coaxt=0 ms: physics control control reads 0.0 (age 0 ns, none)t=1 ms: physics telemetryt=2 ms: physics control control reads 0.2 (age 0 ns, none)t=3 ms: physicsafter a pause, control at 8 ms reads 0.0 (age 5000000 ns, stale)The library's own check compares 60 ticks of a three-task schedule with an independent reference trace: it expands every task's run times, sorts them by time and declaration order, and requires the same 110 runs in the same order.
Astronomical time scales
UTC follows the Earth's rotation, so it gains a leap second from time to time. TAI counts SI seconds without leap seconds. TT is TAI plus exactly 32.184 s. TDB, the time argument of planetary ephemerides, differs from TT by a periodic term under 2 ms.
utc_to_taiadds TAI − UTC from a pinned table: 10 s from 1972-01-01 and the 27 leap seconds through 2017-01-01. A UTC instant counts POSIX nanoseconds, so the leap second itself (23:59:60) has no UTC instant here.- The table's identity,
LEAP_TABLE_ID, is an FNV-1a hash of its rows and its end. Each converted instant carries it inScaled(TAI).table. A different table is a different identity. - The table covers 1972-01-01 up to, but not including, 2026-06-28, the expiry of the IERS leap-second list it was checked against. An instant outside that coverage is refused with
before_tableorafter_table. A newer list extends the coverage under a new identity. tt_to_tdbadds TDB − TT from the series of USNO Circular 179, equation 2.6, which the circular gives as good to about 10 µs from 1600 to 2200.
The program `examples/ch30_scales.coax` converts five UTC instants:
$ coax run examples/ch30_scales.coaxleap-second table 73346933547955834792016-12-31T23:59:59Z: TAI-UTC 36000000000 ns, TT-UTC 68184000000 ns, TDB-TT -45649 ns2017-01-01T00:00:00Z: TAI-UTC 37000000000 ns, TT-UTC 69184000000 ns, TDB-TT -45648 ns2026-01-01T00:00:00Z: TAI-UTC 37000000000 ns, TT-UTC 69184000000 ns, TDB-TT -80496 ns1971-12-31T00:00:00Z: refused, before_table2026-07-01T00:00:00Z: refused, after_tableTT − UTC is 69.184 s after 2017-01-01, the value IERS publishes. The 2026-07-01 instant is past the table's coverage, so it's refused rather than converted with a guess. The library checks TAI − UTC on both sides of the 1972-07-01 and 2017-01-01 leap seconds, TT − UTC against the published value, and days_from_civil against day-by-day counting from year −803 to 2103. The TDB values are checked against the series itself and its bound; a comparison with a full ephemeris time series is not part of this profile.
Time warp stops at every event
A warp factor scales simulation time against steady time. `warp_step(now, steady_ns, warp, next_event)` returns the simulation step for one steady step, capped at the next event:
warp_step :: (now: Instant(Sim), steady_ns: s64, warp: s64, next_event: Instant(Sim)) -> s64 { room := next_event.ns - now.ns; if steady_ns < 1 || warp < 1 || room < 1 { return 0; } if warp > room / steady_ns { return room; } return steady_ns * warp;}The program `examples/ch30_warp.coax` steps 1 ms host frames through four events at warp 1 and at warp 10⁶:
$ coax run examples/ch30_warp.coaxwarp 1: event 0 at 3500000 ns, event 1 at 10000000 ns, event 2 at 10000001 ns, event 3 at 2000000000 ns, 2002 stepswarp 1000000: event 0 at 3500000 ns, event 1 at 10000000 ns, event 2 at 10000001 ns, event 3 at 2000000000 ns, 4 stepsWarp 10⁶ takes 4 steps instead of 2,002, and lands on the same events at the same instants in the same order, including two events 1 ns apart. Chapter 32 adds event location for events that a solver has to find.
Reading a clock
No procedure in coax/lib/clock.coax reads a clock. The host reads its clocks and passes instants in, so the code that computes with time stays free of clock reads. coax deps FILE --effects reports no foreign call (bit 2) for any of the library's procedures. Making a clock read an effect that the compiler tracks and refuses in pure code is R11 work.
What remains planned
- The task syntax: `control :: task @rate(hz=500) (q: Hold(JointState, max_age=4ms))
. Today a schedule is aRate_Task` array and a connection is aHoldvalue. - Clock reads as compiler-checked effects (R11).
- Adoption: the simulated robot's physics and control steps and the Metaverse's fixed-step update driven from declared schedules (Metaverse Engine chapter 1), and recorded clock boundaries for replay (chapter 33).